rev 2020.11.5.37957, The best answers are voted up and rise to the top, Home Improvement Stack Exchange works best with JavaScript enabled, Start here for a quick overview of the site, Detailed answers to any questions you might have, Discuss the workings and policies of this site, Learn more about Stack Overflow the company, Learn more about hiring developers or posting ads with us.

Also, do you live someplace you might need heat in basement and consider how to tap into your system if so. Hello all, I am adding two small baths and I need to cut into an existing 8" inch duct and branch off for the new baths. I have an old gas heater that I would like to keep for standby that used 1" copper plumbing. My professor told us a previous version of our textbook would be okay, but has now decided that it isn't? All information is provided "AS IS." Because of this the downstairs unit is running overtime to compensate. Why would a compass not work in my world? 1995-2018 MH Sub I, LLC dba Internet Brands. My neighbor thought the problem might be with the insulation around the handler, but I find that hard to believe. problems contact [email protected]. What is the main difference between a decoder and a demultiplexer, Algorithm for Apple IIe and Apple IIgs boot/start beep. The other 10' wall faces North and is shaded 24/7 by trees. Given the start up noises we had with the A/C, I wondering if is it possible that the output of the new AC is too much the air handler to handel? Basically you are trying to balance your new ducts with respect to your old ducts by sizing the new ducts.

How do I eliminate the cold drafts coming from my air conditioning vents during winter? I could tap into one of these to run both office ducts or tap into each duct run for a single duct run into the office. Return can be just about any thing (in my area). Copyright© Website operating Thank you. 2) I have two ducts from the supply duct that run to the kitchen and living room. I know this is a lot of questions, but any comments would be greatly appreciated.. John. A new duct run would be about 30-35' long. I recently closed off a new section of my house to create a new room. What is your opinion? Also should I run two different new lines off of the existing line or would one be ok. I had my units inspected this spring and the tech said that the t-stat upstairs was bad, but that overall my systems looked good. From what I recall about the heater, it may have a dial which is used to adjust the temperature swing range (the high and low). Could keeping score help in conflict resolution?

Any thoughts on how to troubleshoot this? Where should I tap in to the existing duct work? I know booster fans for the ducts leading to rooms rarely work. Can I move second-floor duct-work from the floor to the attic.

DoItYourself.com®, founded in 1995, is the leading independent I could tap into one of these to run both office ducts or tap into each duct run for a single duct run into the office. to this site, and use it for non-commercial use subject to our terms of use. Home Improvement Stack Exchange is a question and answer site for contractors and serious DIYers. Music system speakers, plumbing or a/c ductwork changes, alarm system, etc. I was thinking that if I put both baths on the same line the air flow would not be enough and you would be able to hear almost everything from one bath to the other through the ducts.. Also would flexible duct be alright for this application. We keep the thermostat at 78degrees.

To learn more, see our tips on writing great answers. Is this existing 8 inch duct presently serving a terminal register? I do not have the cash right now to insulate the other 2 dry-walled walls with blown in insulation.

Does the sun's rising/setting angle change every few months? 2) I have two ducts from the supply duct that run to the kitchen and living room. Also, before you do it, consider if there's anything else you might want to do throughout your house that would require access to the basement ceiling. Thanks for any info in advance, HI, I do not heat my hot water with the furnace. It IS an interesting application of geometry laying out the three-dimensional object in two dimensions on a piece of sheet metal. I am guessing 8". Tapping into existing Duct ? Or, will it have no real effect? How has the first atomic clock been calibrated? Creating new Help Center documents for Review queues: Project overview. I am located in Dallas so right now temps are running 95 to 105 degrees F. I have a Goodman (Furnace: GMS80603AN/Outside Unit: VSX130361) central air 3.0 ton system (Cool is electric & Heat is natural gas) which, according to specs, does 60,000 BTU/h with a max CFM @ 0.5" ESP of 1200. If you make a mistake or if your relative cooling loads (office vs rest of the house) ever changes, your only recourse would be to replace the ducts. I would like to branch off of the existing duct at 90 degees . I have two AC units in my house. What is your opinion? One for upstairs and one for downstairs. Several months ago we replaced the A/C unit and we had all sorts of problems with A/C start up noises. problems contact [email protected]. And last take off should be two feet from end of duct. Is a lightfoot halfling obscured for the purposes of hiding while in the space of another creature? The new runs would both be less than 6 feet from the existing 8 inch line.. The front of the garage is insulated (10') along with the wall attached to the house (20'). How to repair buckled duct work inside wall? Asking for help, clarification, or responding to other answers. I would appreciate any ideas on how to stop the condenstaion.

Questions of a Do It Yourself nature should be submitted to our "DoItYourself.com Community Forums". It's 113 today. I'm adding the ... My second floor, where the bedrooms are at, is somewhat stuffy. How to Cut Into HVAC Ductwork.

I enclosed the one car garage (10'x20') @ 200 SQFT to serve as an office. The duct I wanted to tap does serve a terminal register. All rights reserved.

Okay, this will not be too bad.

Heating and cooling ductwork distributes warm or cold air throughout a house, but it must be properly installed to be effective. eb, AC cycles on but does not run long enough. Since you have 12" duct and a place to attach them, just get a damper like this: http://www.grainger.com/Grainger/DAYTON-Round-Balancing-Damper-2TFY1?Pid=search. A type of compartment that rises out of a desk, how to append public keys to remote host instead of copy it. You may be able to find 8 inch saddles at a sheet metal shop (or they could make them up for you) or you could try making them yourself. site design / logo © 2020 Stack Exchange Inc; user contributions licensed under cc by-sa. Supply air will have to be duct.

home improvement and repair website. The house measures around 900 SQFT. I am in the process of finishing my basement and I would like to tap into the existing runs.

I had a new air handler installed 3 years ago, its in the ceiling of the garage. But, will a booster fan help get that air to the air handler? If my Supply duct is a rectange - say 15 feet long by 2 feet wide and 1 foot deep. Should I insulate metal duct work in basement? We welcome your comments and To subscribe to this RSS feed, copy and paste this URL into your RSS reader. By using our site, you acknowledge that you have read and understand our Cookie Policy, Privacy Policy, and our Terms of Service. suggestions. home improvement and repair website. The problem seems to be fixed with the addition of an A/C pad under the unit. By clicking “Post Your Answer”, you agree to our terms of service, privacy policy and cookie policy. Issue between main and pool sub-panel; main breaker trips w/o power on at... Change the handing of an old dexter latch. I have adjusted the dampers and registers to increase the airflow up there and it has helped. I will be tapping into my A/C Ducting in my upstairs attic (the two attics connect). Is there a such thing as a 90 degree sadle that I could buy to tap into the existing 8 inch round duct? One of the non-insulated walls (20') faces West and gets pretty hot in the late afternoon.